Figure 1

SOLENOID VALVE INSTALLATION

1.

Connect the vacuum hose and fuel pipe to the solenoid valve.

2.

Install the solenoid valve on the bracket as shown in Figure 1.

3.

Disconnect the vacuum hose from the surge tank.

4.

Connect the fuel pipe to the surge tank. Clip the pipe to the bracket.

5.

Connect the vacuum hose to the to the vacuum hose which was disconnected in Step # 3. Clip the hose to the bracket.