Air Cleaner Fresh Air Duct/Hose: Service and Repair

REMOVAL

1. Disconnect the vacuum hose.

2. Remove the air cleaner outlet tube.

1

Loosen the band clamps.

2

Disconnect the breather tube inlet hose and the bypass air inlet hose.

3

Disconnect the transaxle vent tube.

3. Transfer the upper and lower resonators.

INSTALLATION

1. To install, reverse the removal procedure.

Air Flow Meter/Sensor > < Accelerator Pedal|Pedal|Page 3786