Fluid - M/T: Service and Repair

Note:  Transmission at operating temperature.

Replace sealing washers on drain and filler/level plugs.

Remove drain plug (1) and allow oil to stop draining. 

Clean drain plug and refit. 

Tightening torque:  32-40 Nm

Remove filler/level plug (2) and top up transmission until oil overflows, allow oil to stop draining and refit filler/level plug. 

Tightening torque:  20-30 Nm.