mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Solar Sensor, HVAC|Service and Repair
Page 1
background image

Service Port HVAC: Service and Repair

64 53 Replacing Valve Insert For Refrigerant Line

WARNING:
Risk of injury.
Refrigerant circuit is under high pressure.

Follow safety instructions for handling refrigerant R 134a.
Follow safety instructions for handling refrigerant oil.
Avoid contact with refrigerant and refrigerant oil.

IMPORTANT:  Risk of damage.

Restart engine only when A/C system has been correctly filled.
Follow instructions for opening and replacing parts in refrigerant circuit.
If A/C system is opened for more than 24 hours:Replace desiccant insert for A/C system

NOTE:

The special tool is available under BMW order number:
81 34 0 427 679 from the BMW workshop equipment catalogue.

Necessary preliminary tasks:

-

Drawing off, evacuating and filling the A/C system are not included in the time value given for this work operation

Twist valve insert out of filler neck (2) with remover (1).

Installation:

Screw in valve insert hand-tight only.

After installation:

-

Evacuate and fill A/C system

-

Check leak-tightness of valve insert with soapy solution
In event of leakage:
-

Evacuate A/C system

-

Check sealing faces on line and valve insert for damage, replace line or valve insert if necessary

Solar Sensor, HVAC > < Solar Sensor, HVAC|Service and Repair