Unscrew nut (1).
Tightening torque
1AZ Battery positive lead to B+ multifuse distributor
M6 ............................................................................................................................................................................................................ 8 Nm ±1 Nm
Type: R55 / R56
Disconnect plug connections (2) and remove B+ distributor (3).
Installation:
Plugs are colour- and mechanically coded.
Ensure correct contacting.
B+ distributor can only be replaced as a complete unit (with fuses).