Cooper Convertible (R52) L4-1.6L (W10) (2005)
Service Port HVAC: Service and Repair
64 53 ... - Replacing valve insert for refrigerant line
Warning!
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling refrigerant R 134a See: Service and Repair/Procedures/Instructions for Handling Refrigerant R 134a.
Follow safety instructions for handling refrigerant oil See: Service and Repair/Procedures/Instructions for Handling Refrigerant Oil (for Refrigerant R
134a).
Avoid contact with refrigerant and refrigerant oil.
Important!
Risk of damage!
Restart engine only when A/C system has been correctly filled.
Follow instructions See: Service and Repair/Removal and Replacement for opening and replacing parts in refrigerant circuit!
If A/C system is opened for more than 24 hours:Replace desiccant insert for A/C system See: Receiver Dryer/Service and Repair/Removing and
Installing/Replacing Drier Bottle for Air Conditioner
Note:
The special tool is available under BMW order number: 81 34 0 427 679 from the BMW workshop equipment catalogue.
Necessary preliminary tasks:
-
Drawing off, evacuating and filling the A/C system See: Service and Repair/Procedures/Drawing Off, Evacuating and Filling A/C System (R 134a)
are not included in the time value given for this work operation