Cooper Convertible (R52) L4-1.6L (W10) (2005)
To install contacts, observe cavity numbers on reverse side of socket housing.
Socket Housings, 2x21-, 2x27-pin, Hybrid Systems MQS/MPQ, Elo/Elo-Power
61 13 ... - Socket housings, 2x21-, 2x27-pin, Hybrid Systems MQS/MPQ, Elo/Elo-Power
Manufactured by AMP: The following contact types without strand sealing can be fitted in the socket housings:
-
MQS (Micro Quadlock System)
-
MPQ, width 2.8 mm (Micro Power Quadlock)
-
MPQ, width 5.2 mm (Micro Power Quadlock)
Manufactured by Siemens: The following contact types without strand sealing can be fitted in the socket housings:
-
Elo (electronic contact)
-
Elo-Power 2.8 mm wide (electronic contact for heavy loads)
-
Elo-Power 5.2 mm wide (electronic contact for heavy loads)
Raise lock (1) on housing (2).
Push contact carrier (3) from rear out of housing.
Note:
The second contact carrier is pushed out in the same way.
Pushing out the contact carrier releases the secondary locks of the socket contacts.