mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Compressor HVAC > < Maintenance - Condition Based Service (CBS) Overview|Page 6514
Page 1
background image

Climate Control Exhaust Gas Sensor: Service and Repair

64 11 991 - Removing and installing/replacing sensor for automatic recirculated air control

Necessary preliminary tasks:

-

Remove right cowl panel cover

Disconnect plug connection (1).
Unclip retaining notch (2) and turn sensor (3) in direction of arrow out of mounting.

Installation:

Make sure sensor (3) is correctly seated in locator.

Compressor HVAC > < Maintenance - Condition Based Service (CBS) Overview|Page 6514