Cooper Convertible (R57) L4-1.6L (N12) (2009)
Power Distribution Module: Recalls
Campaign - FRM Reprogramming
SI M61 02 09
General Electrical Systems
May 2009
Technical Service
This Service Information bulletin supersedes S.I. M61 02 09 dated May 2009.
PERFORM THE PROCEDURE OUTLINED IN THIS SERVICE INFORMATION ON ALL AFFECTED VEHICLES THE NEXT TIME THEY ARE
IN THE SHOP FOR MAINTENANCE OR REPAIRS AND PRIOR TO RETAIL DELIVERY.
[NEW] designates changes to this revision
SUBJECT
Service Action: Program Control Modules (FRM)
MODEL
R57 (MINI Convertible)
SITUATION
An error in the footwell module (FRM) software may lead to a loss of window initialization.
When window initialization is lost, the window remains in the short lift position when the door is opened, and the convertible top cannot be opened.
CAUSE
FRM software error
AFFECTED VEHICLES
This Service Action involves R57 (MINI Convertible) vehicles, which were produced from November 11, [NEW] 2008 to April 2009.
In order to determine whether a specific vehicle is affected by this Service Action, it will be necessary to utilize the "Service Menu" of the DCS (Dealer
Communication System) or the Key Reader. Based on the response of the system, either proceed with the corrective action or take no further action.
The chassis number ranges shown above are only for informational purposes, and are not to be considered as the only deciding factor.
PROCEDURE
Program the vehicle using ISTA/P 2.33.2 or later.
Note that ISTA/P will automatically reprogram and code all programmable control modules that do not have the latest software.
For information on programming and coding with ISTA/P, refer to Centernet / Aftersales Portal / Service / Workshop Technology / Vehicle
Programming.
LABEL INSTRUCTIONS
This Service Action has been assigned code number 42. After the vehicle has been checked, and corrected if necessary, obtain a label (MD 20-036) and: