Climate Control Exhaust Gas Sensor: Service and Repair

64 11 991 - Removing and installing/replacing sensor for automatic recirculated air control

Necessary preliminary tasks:

-

Remove right cowl panel cover See: Body and Frame/Cowl/Cowl Moulding / Trim/Service and Repair/Removing and Installing / Replacing Right
Cowl Panel Cover

Disconnect plug connection (1).
Unclip retaining notch (2) and turn sensor (3) in direction of arrow out of mounting.

Installation:

Make sure sensor (3) is correctly seated in locator.