mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Wiring Harness > < Fusible Link|Locations|Page 10021
Page 2
background image

Release SBK terminal connector (1) from fuseable link housing.
Remove nut (2) securing battery cable to fuseable link terminal and release cable (3).
Tightening torque 13 Nm.
Remove fuseable link housing (4) from body by lifting up (as shown) and then forward.
Replacement only:
Remove nut (5) securing fuse to fuseable link terminal.
Tightening torque 15 Nm.
Remove fuse (6).
Remove nut (7) securing battery cable to fuseable link terminal and remove cable (8).
Tightening torque 13 Nm.

Install hint:
Fit new battery positive cable in the reverse order of the above. Start from the front, working rearwards.
Connect up the battery in reverse sequence. First connect the positive lead and then the negative lead.
Reset clock.
Initialise both window regulators.

Wiring Harness > < Fusible Link|Locations|Page 10021