mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Base of Tab Connector Housings|Page 10081 > < Base of Tab Connector Housings|Page 10079
Page 2
background image

Open pliers (1).

NOTE:  Place contact (2) with utmost care in designated nest (observe cable cross-section) in crimping head (3). Make sure it is exactly positioned.

Place MPQ contact (2) in crimping head (3).
Close pliers (1) one notch.

NOTE:  Follow procedure for cutting and stripping insulation from cables.

Insert stripped cable (2).
Close pliers (1) fully.
Open pliers (1) and remove cable (2).

NOTE:

Check contact for correct crimping.

Crimping Micro Quadlock System Contacts (MQS)

Crimping Micro Quadlock System Contacts (MQS)

Special tools required:

-

61 4 320

To crimp MQS contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 324 (2) from crimping set 61 4 320.

NOTE:  Pliers (1) open automatically as far as they will go when handles are pressed together.

Base of Tab Connector Housings|Page 10081 > < Base of Tab Connector Housings|Page 10079