mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Recall - Reprogramming DME for EVAP Leak Diagnostics|Page 8590 > < Recall - Reprogramming DME for EVAP Leak Diagnostics|Page 8588
Page 3
background image

R50 Cooper CVT: programmed number 7547052, basic number 7527610;

R53 Cooper S: programmed number 7547054, basic number 7527610.

[NEW] To reprogram the EMS2000 control module on Cooper CVT UP TO 10/03 production and Cooper S John Cooper Works kit vehicles:

1.

Connect a battery charger.

2.

Connect GT1 loaded with CD 38.0, or higher.

3.

Select: Coding/Programming.

4.

Select: 5 Programming, then the right arrow.

5.

Select: 1 DME Programing, then the right arrow.

6.

Select 2 Exchange Control Unit, then the right arrow.

7.

Display appears First determine and then program basic control unit, then the right arrow.

8.

Select 1 Determine basic control unit, then the right arrow. Automatic determination is going to be performed.

9.

DME ESM2000 is the faulty control unit still installed in the car?, select NO.

10.

On the next screen, select right arrow.

11.

Enter basic control unit part number) enter: 7527610 Number correct? Select YES.

12.

On the next screen select the right arrow.

13.

Enter full VIN) Number correct? Select YES.

14.

Enter program control unit part number) enter: 7547052 (for Cooper CVT) enter: 7547870 (for Cooper S John Cooper Works kit) Number
correct?

Select YES, then scroll down till the end, and to the left. At this point basic and programmed control unit part numbers are stored for
programming.

15.

Select: Program basic control module, then the right arrow.

16.

Follow instructions for entering the last seven characters of the VIN. Select YES.

17.

Switch on ignition, then right arrow twice.

18.

The next screen displays: The control module can be programmed X time), then the right arrow.

19.

Follow the command for mileage entry Entry correct?. Select: YES.

20.

DME EMS2000 Start automatic programming) Select: YES).

21.

After successful programming, message is displayed: Programming completed.

22.

Important: at this point turn ignition off and perform battery reset (disconnect battery cable) for 30 seconds. After that, reconnect battery.

23.

Recode EMS2000 control module. Select 3 Coding ZCS/FA.

24.

Select R50/R53, then the right arrow.

25.

Select 1 Recoding, then the right arrow.

26.

Select 95 MOTRONIC, then the right arrow.

27.

Selection correct? Select YES.

28.

Motronic start automatic coding? Select YES.

Recall - Reprogramming DME for EVAP Leak Diagnostics|Page 8590 > < Recall - Reprogramming DME for EVAP Leak Diagnostics|Page 8588