mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Seat Heating|Page 9864 > < Seat Heating|Page 9862
Page 2
background image

lamp are also built in.

Heater/air conditioner

The IHKA heater/air conditioner is fitted underneath the instrument cluster in the centre, at the front bulkhead. The heater/air conditioner performs the
tasks:

-

Generation and regulation of air quantity

-

Air distribution, air mixture (stratification) and air dehumidification

-

Transfer of refrigerating output generated by the cooling circuit

-

Transfer of heat output delivered by the refrigerant circuit

The heater/air conditioner is composed of the following components:

-

Evaporator
The evaporator plates are cooled by the coolant evaporating inside. The air-mass flow supplied by the blower is guided over the cool evaporator
plates. The air is cooled and dried and guided into the vehicle interior.

-

Heat exchanger for heating system and heating system heat exchanger sensor
The heating system heat exchanger sensor is fitted directly behind the heat exchanger for the heating system. The heating system heat exchanger
sensor measures the temperature of the heat exchanger for the heating system.

-

Flaps with drive and mechanical system
The flap motors are connected directly to the IHKA control module. Three flap motors are fitted in the IHKA. The flaps serve to distribute the air
and to mix hot and cold air.
Fresh air recirculated-air flap: the amount of clean air drawn in by the blower is regulated with this flap.
Air distribution flap: The air distribution flap mechanical system mechanically adjusts the air distribution flaps. The air distribution flap
mechanical system is driven by the air distribution flap motor.
The air distribution flap motor has the task of setting the air distribution by means of a cam disk. The air distribution flap motor has no detection of
the actual position. In order to ensure unique positioning of the cam disk nonetheless, there are 2 cams of different widths on the cam disk. The
micro-switch signals to the IHKA control module that the cams have been passed over. This mechanism achieves reliable and rapid positioning of
the cam disk.
Temperature mixing flap: The air-mass flow is guided through the evaporator. The airmass flow is cooled and dried in the evaporator (when the air
conditioning system is switched on). Subsequently, the temperature mixing flap guides the air-mass flow (depending on the set desired temperature
value in the IHKA controls) fully or partially over the heat exchanger for the heating system and the electrical auxiliary heater (diesel engine).

-

Blower with blower output stage
The blower creates the necessary air-mass flow. The blower is fitted after the fresh air recirculated-air flap in the heater/air conditioning system
(pressing blower arrangement). The blower output stage is mounted directly at the housing of the blower motor. The blower output stage is
activated by the IHKA control module with a pulse-width modulated signal (PWM signal). The blower output stage is not diagnosis-capable.

-

Electrical auxiliary heater
The electrical auxiliary heater based on the PTC principle (positive temperature coefficient) is fitted in the heater/air conditioner. The electrical
auxiliary heater directly heats up the air to adjust the temperature of the vehicle interior. The electrical auxiliary heater is only fitted in diesel
engines.

Radiator fan

The radiator fan and the engine cooling are also required for cooling the condenser. The radiator fan is activated by the Digital Engine Electronics
(DME).

A/C compressor

The air-conditioning compressor compresses the refrigerant taken in by the evaporator. The refrigerant is pressed towards the condenser. The
air-conditioning compressor is switched by the compressor coupling. Activation is initiated by the IHKA control module.

Condenser with integrated drier flask

In the condenser, gaseous refrigerant is converted into liquid refrigerant. In the integrated downstream drier flask, any water present in the refrigerant
circuit is bound. The drier insert can be replaced.

Sensors

-

Internal temperature sensor
The internal temperature sensor is built into the IHKA control module. The internal temperature sensor measures the temperature in the control
module. This measured temperature is used by an integrated mathematical model to calculate the value for the interior temperature.
The internal temperature sensor is not force-ventilated. This means that no internal temperature sensor fan is fitted in the IHKA control module.

-

Solar sensor
The solar sensor consists of a photo diode. The solar sensor picks up external light or heat sources (e.g. sunlight). The solar sensor provides the
IHKA control module with an analog signal depending the intensity of the sunlight in each case. Adaptation to the sunlight is only active in the
automatic program. The solar sensor is fitted in the centre of the instrument panel.

-

Sensor for automatic recirculated air control