Notes for Service department

Diagnosis instructions for the trailer module

The trailer module detects and reacts to the following faults:

-

Checksum fault of the various memories and watchdog reset

-

Faults of the CAN drivers

-

Wire faults of the CAN interface and of the brake light input

-

Wire fault of all outputs with short circuit and wire break

-

Undervoltage / overvoltage and implausibility of the control module voltage in comparison with the on-board supply voltage

-

Implausibility of a CAN message "Braking" compared to the hard-wired brake light input at the control module

-

Implausibility of the sense values of the lighting outputs of the control module

-

Faults on the lamp outputs of the trailer module are output as Check Control messages

Notes on encoding / programming

After installation of a trailer module, the control module must be re-encoded. In doing so, observe the various national versions.

No liability can be accepted for printing or other faults. Subject to changes of a technical nature.

Supply, AHM Trailer Module

AHM_70 - Description Of Short Circuit Behaviour

Dealing with short circuits in the trailer module AHM_70

Monitoring in general: A short circuit, a break in wiring or the proper function of a circuit can be detected at any output of the trailer module.

Detecting a short circuit, checking it and making a fault memory entry take approx. 5 seconds if the output is switched on.

It also takes approx. 5 seconds to detect a short circuit as no longer present if the output is switched on.

Description for dealing with short circuits in the trailer module:

If a short circuit is detected, the output is switched off.

Following repair, a terminal change must take place and the light must be switched on again so that the corresponding output is reactivated.

If this operation has taken place 50 times, the fault entry "permanent short circuit fault" can no longer be deleted. The trailer module must be replaced.