Cooper S Convertible (R57) L4-1.6L Turbo (N14) (2009)
/l4-1.6l_turbo_(n14)/Page-1457001.png)
Service Port HVAC: Service and Repair
64 53 ... - Replacing valve insert for refrigerant line
Warning!
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling refrigerant R 134a See: Service and Repair/Procedures/Instructions for Handling Refrigerant R 134a.
Follow safety instructions for handling refrigerant oil See: Service and Repair/Procedures/Instructions for Handling Refrigerant Oil (for Refrigerant R
134a).
Avoid contact with refrigerant and refrigerant oil.
Important!
Risk of damage!
Restart engine only when A/C system has been correctly filled.
Follow instructions See: Service and Repair/Removal and Replacement for opening and replacing parts in refrigerant circuit!
If A/C system is opened for more than 24 hours:Replace desiccant insert for A/C system See: Receiver Dryer/Service and Repair/Replacing Desiccant
Insert for A/C System
Note:
The special tool is available under BMW order number: 81 34 0 427 679 from the BMW workshop equipment catalog.
Necessary preliminary tasks:
-
Drawing off, evacuating and filling the A/C system See: Service and Repair/Procedures/Drawing off, Evacuating and Filling A/C System (R 134a)
are not included in the time value given for this work operation