300ZX Coupe V6-2960cc DOHC (VG30DE) (1994)
Inhibitor Switch: Service and Repair
Fig. 3 Inhibitor Switch Adjustment.
Fig. 4 Inhibitor Switch Continuity Inspection.
Fig. 5 Inhibitor Switch Continuity Specifications.
1. Place manual valve in Neutral (vertical position).
2. Remove adjustment cover screw.
3. Loosen switch attaching screws.
4. Using suitable alignment pin, move switch until pin falls into hole in rotor, Fig. 3.
5. Tighten attaching bolts, then while moving selector lever through all gear ranges, check switch for continuity as shown in Fig. 4.
6. Compare results with Fig. 5.
7. If switch does not operate as specified, replace switch.