nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 7846 > < Diagram Information and Instructions|Page 7844
Page 1
background image

Variable Valve Timing Solenoid: Description and Operation

System Description

IVT CONTROL

This mechanism hydraulically controls cam phases continuously with the fixed operating angle of the intake valve. 

The ECM receives signals such as crankshaft position, camshaft position, engine speed, and engine coolant temperature. Then, the ECM sends ON/OFF
pulse duty signals to the camshaft timing control valve depending on driving status. This makes it possible to control the shut/open timing of the intake
valve to increase engine torque in low/mid speed range and output in high-speed range.

IVT CONTROL SOLENOID VALVE

 

Intake valve timing control solenoid valve is activated by ON/OFF pulse duty (ratio) signals from the ECM. 

The intake valve timing control solenoid valve changes the oil amount and direction of flow through intake valve timing control unit or stops oil flow. 

The longer pulse width advances valve angle. 

The shorter pulse width retards valve angle. 

Diagram Information and Instructions|Page 7846 > < Diagram Information and Instructions|Page 7844