350Z V6-3.5L (VQ35) (2003)
a.
From the listed items, find and select "BATTERY CHARGE".
3.
Check the CONSULT-II's "Charger Input" reading (see Figure C).
NOTE:
^
"Battery Voltage" is the voltage level of CONSULT-II's battery.
^
"Charger Input" is the voltage level of the vehicle's battery. (It must be above 12 volts.)
IMPORTANT
Do not perform ECU Reprogramming without connecting a battery charger to the vehicle's battery. Permanent ECU damage can occur.
Connecting a vehicle battery charger will maintain:
^
Proper CONSULT-II power supply during reprogramming-very important if the CONSULT-II battery is low.
^
Vehicle battery voltage level-especially on late model vehicles where the cooling fans come on during reprogramming.
Step Three: Reprogram the Vehicle ECM
Step Four: "Wrap-up" After Reprogramming is Finished
1.
Turn the ignition switch "OFF" and CONSULT-II "OFF".
2.
Wait more than 10 seconds, then;
a.
Turn the ignition switch "ON" for 1 second, then
b.
Turn the ignition switch "OFF" again for 10 seconds (see Figure D). This will reset ECM "self learned" Data.