12. Attach cover assembly to pump assembly and tighten four mounting bolts diagonally at the specified torque.
NOTE: Be careful not to damage the thread, do not use the power tool.
13. Install the flow control valve assembly, the relief valve and flow control valve spring to the body assembly.
14. Install O-ring D to the plug, tighten plug at the specified torque.
NOTE: O-ring D is non-reusable part. Never reuse O-ring D.
15. Install O-ring E to the suction connector assembly, and install the suction connector to the body assembly. Tighten one mounting bolt at the
specified torque.
NOTE: O-ring E is non-reusable part. Never reuse O-ring E.
16. Install the bracket to body assembly, and tighten the two mounting bolts at the specified torque.