Altima 2.5 SL L4-2.5L (QR25DE) (2002)
^
After checking the full-open lift amount, lower the water temperature and check the valve closing temperature.
INSTALLATION
Installation is in the reverse order of removal.
^
Install the thermostat with the whole circumference of the flange part fitting securely inside the rubber ring.
^
Install the thermostat with the jiggle valve facing upwards. The position deviation may be within the range of +/-10°.
^
If necessary, to install the heater pipe, first apply a mild detergent to the O-ring and then quickly insert the pipe into the housing