Altima SE L4-2.4L (KA24DE) (1997)
8. Rotate and hold water cock lever and plate in the full cold position (CLOCKWISE completely).
9. Attach water cock cable to plate and secure with clip (white mark on cable housing should be centered under the retaining clip).
10. Check that water cock operates properly when changing from code No. 41 to 46 by pushing DEF switch. (After several cycles, water cock lever
should be midpoint of plate opening when code No. 41 is set.)
Intake Door
INTAKE DOOR
1. Install intake door motor on intake unit and connect it to main harness.
2. Set up code No. 41 in Self-diagnosis STEP 4.
3. Move intake door link by hand and hold it in REC position.
4. Attach intake door lever to rod holder.
Intake Door
5. Make sure intake door operates properly when changing from code No. 41 to 46 by pushing DEF switch.
Fresh Vent Door
FRESH VENT DOOR
1. Install fresh vent door motor on cooling unit and connect it to main harness.
2. Set up code No. 46 in Self-diagnosis STEP 4.
3. Move fresh vent door link by hand and hold it in CLOSE position.
4. Attach fresh vent door lever to rod holder.
Fresh Vent Door
5. Make sure fresh vent door operates properly when changing from code No. 41 to 46 by pushing DEF switch.