nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

A/C - Poor Performance, Suction Side Shows Low or Vacuum|Page 8714 > < A/C - Poor Performance, Suction Side Shows Low or Vacuum|Page 8712
Page 3
background image

4.

Evacuate, then recharge the system with 1.54-1.76 lbs (0.70-0.80 kg) of R134a refrigerant.

5.

Conduct a leak check and an A/C performance test to ensure proper repair.

Repair Procedure # 2 (Loose Desiccant Incident)

1.

Use suitable recovery equipment to recover the refrigerant as recommended in the service manual.

2.

Remove the following (see Figure 1):

^

Liquid tank

^

High cooler pipe (from the liquid tank outlet to evaporator inlet)

^

Evaporator inlet tube

^

Expansion valve.

NOTE:  The high cooler pipe could be a one or two piece pipe depending on whether the A/C was factory- or kit-installed. The service
replacement part for the high cooler pipe contains two pieces for ease of installation.

3.

Replace all removed parts with new parts. Torque all joint fittings (see Figure 1).

IMPORTANT:  When replacing parts, observe the following:

^

Replace all parts mentioned in step 2 at the same time because the loose desiccant may settle anywhere along this section when the A/C
system is off.

^

Replenish refrigerant oil. Refer to page HA-21, LUBRICATION OIL - Checking and Adjusting in the 1993 service manual. Refer to page
HA-138, SERVICE PROCEDURES - Maintenance of Oil Quantity in Compressor in the 1994 service manual. Refer to the HA section
under SERVICE PROCEDURES - Compressor Lubricant Quantity in the 1995 - 1997 service manuals.

^

Properly install both expansion valve insulation wraps with new parts.

A/C - Poor Performance, Suction Side Shows Low or Vacuum|Page 8714 > < A/C - Poor Performance, Suction Side Shows Low or Vacuum|Page 8712