Armada 2WD V8-5.6L (VK56DE) Flex Fuel (2009)
8. Install bolts (A), (B) and (C) in control valve with TCM.
-
White Arrow Indices: Front
9. Tighten bolt (1), (2) and (3) temporarily to prevent dislocation.
After that tighten them in order (1 to 2 to 3). Then tighten other bolts.
-
White Arrow Indices: Front
10. Tighten control valve with TCM bolts to the specified torque.
11. Connect A/T fluid temperature sensor 2 connector (A).
12. Securely fasten terminal cord assembly and A/T fluid temperature sensor 2 harness with terminal clips
-
Black Arrow Indices: Terminal clip