Cube L4-1.8L (MR18DE) (2010)
Operation Example
In the following operation example, the combination of the status signals of the combination switch is replaced as follows: INPUT 1 - 5 to "1 - 5" and
OUTPUT 1 - 5 to "A - E".
Example 1: When a switch (TAIL LAMP switch) is turned ON
-
The circuit between OUTPUT 4 and INPUT 5 is formed when the TAIL LAMP switch is turned ON.
-
BCM detects the combination switch status signal "5D" when the signal of OUTPUT 4 is input to INPUT 5.
-
BCM judges that the TAIL LAMP switch is ON when the signal "5D" is detected.
Example 2: When some switches (TURN RH switch, TAIL LAMP switch) are turned ON
-
The circuits between OUTPUT 1 and INPUT 5 and between OUTPUT 4 and INPUT 5 are formed when the
TURN RH switch and TAIL LAMP switch are turned ON.