Solar Sensor: Testing and Inspection

Sunload Sensor

Measure voltage between terminals 16 and 35 at vehicle harness side, using the table below.

Input current mA

Output voltage V

0

5.0

0.1

4.1

0.2

3.1

0.3

2.2

0.4

1.3

0.5

0.4

^  When checking sunload sensor, select a place where sun shines directly on it.