nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Low-Pressure Flexible Hose|Page 6930 > < Low-Pressure Flexible Hose
Page 2
background image

CAUTION:  Cap or wrap the joint of the pipe with suitable material such as vinyl tape to avoid the entry of air.

INSTALLATION

Installation is in the reverse order of removal.

Low-pressure flexible hose (evaporator side) bolt: Refer to Exploded View ATC-132.

Low-pressure flexible hose (compressor side) bolt: Refer to Exploded View ATC-132.

Low-pressure flexible hose (in-line connection) bolt: Refer to Exploded View ATC-132.

CAUTION:

-

Replace the O-ring of the low-pressure flexible hose with a new one, then apply compressor oil to it when installing it.

-

After charging refrigerant, check for leaks. Refer to ATC-140, "Checking for Refrigerant Leaks".  See: Testing and Inspection/Component
Tests and General Diagnostics/Checking for Refrigerant Leaks

Low-Pressure Flexible Hose|Page 6930 > < Low-Pressure Flexible Hose