Maxima V6-3.5L (VQ35DE) (2007)
-
through main power window and door lock/unlock switch terminal 14 or power window and door lock/unlock switch RH terminal 16.
The main power window and door lock/unlock switch receives a ground signal
-
to main power window and door lock/unlock switch terminal 17
-
through grounds M57, M61 and M79.
The power window and door lock/unlock switch RH receives a ground signal
-
to front power window and door lock/unlock switch terminal 11
-
through grounds M57, M61 and M79.
When the front door LH is unlocked by the front door lock assembly LH (key cylinder switch), BCM receives serial data
-
to BCM terminal 22
-
through main power window and door lock/unlock switch terminal 14.
And the main power window and door lock/unlock switch receives a ground signal
-
to main power window and door lock/unlock switch terminal 6
-
through front door lock assembly LH (key cylinder switch) terminal 6
-
through front door lock assembly LH (key cylinder switch) terminal 5
-
through grounds M57, M61 and M79.
When a signal or combination of signals is received by BCM, ground is supplied
-
to personal lamp terminals 4 and 6
-
through interior room lamp (room/map lamps) terminal 5, and
-
to interior room lamp (room/map lamps) when interior room lamp switch is in AUTO
-
through interior room lamp (room/map lamps) terminal.
With power and ground supplied, the interior lamp illuminates.
SWITCH OPERATION
When front door switch LH is ON (door is open), ground is supplied
-
to ignition keyhole illumination terminal 2
-
through BCM terminal 1.
And power is supplied
-
through BCM terminal 56
-
to ignition keyhole illumination terminal 1.
When any door switch is ON (door is open), ground is supplied
-
to front and rear step lamp LH and RH terminal 2
-
to foot lamp LH and RH terminal 2
-
through BCM terminal 62.
And power is supplied
-
through BCM terminal 56
-
to every step lamp terminal 1.
When personal lamp switch is HI/LO, ground is supplied
-
to personal lamp terminal 5
-
through grounds M57, M61 and M79.
And power is supplied
-
through BCM terminal 56
-
to personal lamp LH and RH terminal 2.
When map lamp switch LH or RH is ON, ground is supplied
-
to map lamp LH and RH terminal 4
-
through grounds M57, M61 and M79.
And power is supplied
-
through BCM terminal 56
-
to map lamp LH or RH terminal 7.
When vanity mirror lamp (LH or RH) is ON, ground is supplied
-
to vanity mirror lamp (LH or RH) terminal 2
-
through grounds M57, M61 and M79.