Maxima GLE V6-2968cc 3.0L DOHC MFI (VQ30DE) (1997)
6. Perform each diagnostic item according to the item application chart.
Data Lines Open Circuit Check
Data Lines Open Circuit Check
NOTE: When checking data line circuit, disconnect BCM and all LCU connectors.
1. Disconnect BCM and LCU connectors.
2. Check continuity between BCM and LCU terminals.
Data Lines Short Circuit Check
Data Lines Short Circuit Check
1. Disconnect BCM and all LCU connectors.
2. Check continuity between BCM terminal and body ground.
Data Lines Short Circuit Check
3. Check voltage between BCM terminal and body ground.