Maxima GXE V6-3.0L (VQ30DE) (1999)
Fail-safe System
Fail-safe system operates when the signal from LCU is judged to be malfunctioning by BCM. If LCU sends no signal or an abnormal signal to BCM a
certain number of times in succession, the IVMS is set in a fail-safe condition. In the fail-safe condition, no electrical loads on the questionable LCU will
operate.
On Board Diagnostic Results Indicator Lamp
On-Board Diagnostic Results Indicator Lamp
The interior lamp and step lamps (front seats) act as the indicators for the on-board diagnosis. These lamps blink simultaneously in response to
diagnostic results.
On-Board Diagnostic Function
NOTE:
-
When ON BOARD diagnosis is operating, some systems under IVMS control do not operate.
-
The step lamp of malfunctioning LCU does not blink.