Coolant Temperature Sensor / Switch HVAC: Description and Operation
Low Water Temperature Control

Low Water Temperature Control Specifications

CONTROL AT LOW WATER TEMPERATURE

This system activates only when outlet door determined by auto amp. is in "FOOT" or position with "AUTO" switch ON, and with outlet door
control system and fan speed control system activating together.

Outlet door control
When water temperature is less than 30°C (86°F), auto amp. fixes the discharging mode at "DEF". After water temperature reaches more than 30
°C (86°F)
, discharging mode is changed to "FOOT" or "B/L".

Fan speed control
When water temperature is less than 50°C (122°F), auto amp. fixes the fan speed at "LO".

After water temperature reaches more than 50°C (122°F), fan speed is raised to specified fan speed for 5 sec. by starting control.