nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2667 > < Initial Inspection and Diagnostic Overview|Page 2665
Page 9
background image

YES - GO TO 3.
NO - Repair the automatic back door control unit branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the automatic back door control unit. Refer to See: Body and Frame/Locks/Power Locks/Testing
and Inspection/Component Tests and General Diagnostics/Power Supply And Ground Circuit/Automatic Back Door Control Unit.
Is the inspection result normal?
YES (Present error)-Replace the automatic back door control unit. Refer to See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Power
Trunk / Liftgate Control Module/Service and Repair/Removal And Installation.
YES (Past error)-Error was detected in the automatic back door control unit branch line.
NO - Repair the power supply and the ground circuit.

CAN System (Type 2)

PWBD BRANCH LINE CIRCUIT

Diagnosis Procedure

1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the automatic back door control unit for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES - GO TO 2.
NO - Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of automatic back door control unit.
2. Check the resistance between the automatic back door control unit harness connector terminals.

Is the measurement value within the specification?
YES - GO TO 3.
NO - Repair the automatic back door control unit branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the automatic back door control unit. Refer to See: Body and Frame/Locks/Power Locks/Testing
and Inspection/Component Tests and General Diagnostics/Power Supply And Ground Circuit/Automatic Back Door Control Unit.
Is the inspection result normal?
YES (Present error)-Replace the automatic back door control unit. Refer to See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Power
Trunk / Liftgate Control Module/Service and Repair/Removal And Installation.
YES (Past error)-Error was detected in the automatic back door control unit branch line.
NO - Repair the power supply and the ground circuit.

CAN System (Type 4)

PWBD BRANCH LINE CIRCUIT

Diagnosis Procedure

1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the automatic back door control unit for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES - GO TO 2.
NO - Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of automatic back door control unit.
2. Check the resistance between the automatic back door control unit harness connector terminals.

Initial Inspection and Diagnostic Overview|Page 2667 > < Initial Inspection and Diagnostic Overview|Page 2665