7. Disconnect harness connector, fuel feed tube and EVAP hose.
Disconnect quick connector as follows:
-
Hold the sides of connector, push in tabs and pull out fuel feed tube.
A : Pull
B : Push in tabs
-
If quick connector sticks to tube of main fuel level sensor unit, push and pull quick connector several times until they start to move. Then
disconnect them by pulling.
CAUTION:
-
Quick connector (1) can be disconnected when the tabs
(F) are completely depressed. Never twist it more than necessary.
B : Connection (Cross-section)
D : To under floor fuel line
E : To fuel tank
G : Disconnection
-
Never use any tools to disconnected quick connector.
-
Keep resin tube (C) away from heat. Be especially careful when welding near the resin tube.