Refrigerant Pressure Sensor / Switch: Service and Repair

Removal and Installation of Refrigerant Pressure Sensor

REMOVAL

1. Remove the condenser.

2. Remove the refrigerant pressure sensor from condenser.

CAUTION:  When working, be careful not to damage the condenser fins.

INSTALLATION

Installation is basically the reverse order of removal.

CAUTION:  Apply compressor oil to the O-ring of the refrigerant pressure sensor when installing it.

Refrigerant pressure sensor

Tightening torque : 10.8 Nm (1.1 kg-m, 8.0 ft-lb)