nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Housing Assembly HVAC > < Low-Pressure Flexible Hose|Page 9345
Page 6
background image

10. Remove mounting bolt, and then remove low-pressure pipe 2 and high-pressure pipe 2.

CAUTION:  Cap or wrap the joint of the pipe with suitable material such as vinyl tape to avoid the entry of air.

INSTALLATION

Installation is basically the reverse order of removal.

CAUTION:

-

Replace O-rings of A/C piping with new ones, and then apply compressor oil to it when installing it.

-

Connection point for female-side piping is thin. So, when inserting male-side piping, take care not to deform female-side piping. Slowly insert in
axial direction.

-

Insert one-touch joint connection point securely until it clicks.

-

After piping has been connected, pull male-side piping by hand to make sure piping does not come off.

-

When recharging refrigerant, check for leaks.

Low-pressure pipe 1 bracket mounting bolt: 4.2 N.m (0.43 kg-m, 37 in-lb)

Housing Assembly HVAC > < Low-Pressure Flexible Hose|Page 9345