nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Clockspring Assembly / Spiral Cable, Air Bag > < Diagram Information and Instructions|Page 9747
Page 1
background image

Air Bag Control Module: Service and Repair

DIAGNOSIS SENSOR UNIT

Removal and Installation

REMOVAL

CAUTION:  Before servicing SRS, turn ignition switch OFF, disconnect both battery cables and wait at least 3 minutes.

1. Disconnect each harness connector for the air bag module and seat belt pre-tensioner.
2. Remove center console.
3. Disconnect diagnosis sensor unit connector.

4. Remove the bolts from the diagnosis sensor unit.

Hex bolts: 24.5 N.m (2.5 kg-m, 18 ft-lb)
Ground bolt: 6.9 N.m (0.7 kg-m, 61 in-lb)

CAUTION:

-

Do not use old bolts. Replace with new ones.

-

Check diagnosis sensor unit bracket to ensure it is free of deformities, dents, cracks or rust. If it shows any visible signs of damage, replace with
new one.

-

Replace diagnosis sensor unit if it has been dropped or sustained an impact.

INSTALLATION

Install in the reverse order of removal.

CAUTION:

-

Check the diagnosis sensor unit for proper installation.

-

After replacement of diagnosis sensor unit, perform self-diagnosis to make sure no malfunction is detected. Refer to SRS-19, "SRS Operation
Check".  See: Testing and Inspection/Component Tests and General Diagnostics

ECU DISCRIMINATED NO.

After replacing the diagnosis sensor unit, confirm that the diagnosis sensor unit identification is correct for the vehicle as equipped.

Clockspring Assembly / Spiral Cable, Air Bag > < Diagram Information and Instructions|Page 9747