nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

To VIN # 350000|Page 2150 > < To VIN # 350000|Page 2148
Page 2
background image

PRECAUTIONS FOR HANDLING LEAK DETECTOR 

When performing a refrigerant leak check, use a J-41995 A/C leak detector or equivalent. Ensure that the instrument is calibrated and set properly
per the operating instructions.

The leak detector is a delicate device. In order to use the leak detector properly, read the operating instructions and perform any specified 
maintenance.

Other gases in the work area or substances on the A/C components, for example, anti-freeze, windshield washer fluid, solvents and lubricants, may
falsely trigger the leak detector. Make sure the surfaces to be checked are clean. Clean with a dry cloth or blow off with shop air. Do not allow the
sensor tip of the detector to contact with any substance. This can also cause false readings and may damage the detector.

1. Position probe approximately 5 mm (3/16 in) away from point to be checked.

2. When testing, circle each fitting completely with probe.

To VIN # 350000|Page 2150 > < To VIN # 350000|Page 2148