nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Service Port HVAC|Service Precautions|Page 3909
Page 4
background image

-

When connecting tubes, always use a torque wrench and a back-up wrench.

-

After disconnecting tubes, immediately plug all openings to prevent entry of dirt and moisture.

-

When installing an air conditioner in the vehicle, connect the pipes as the final stage of the operation. Do not remove the seal caps of pipes
and other components until just before required for connection.

-

Allow components stored in cool areas to warm to working area temperature before removing seal caps. This prevents condensation from
forming inside A/C components.

-

Thoroughly remove moisture from the refrigeration system before charging the refrigerant.

-

Always replace used O-rings.

-

When connecting tube, apply oil to circle of the O-rings shown in illustration. Be careful not to apply oil to threaded portion.

-

O-ring must be closely attached to dented portion of tube.

-

When replacing the O-ring, be careful not to damage O-ring and tube.

-

Connect tube until you hear it click, then tighten the nut or bolt by hand until snug. Make sure that the O-ring is installed to tube
correctly.

-

After connecting line, conduct leak test and make sure that there is no leakage from connections.
When the gas leaking point is found, disconnect that line and replace the O-ring. Then tighten connections of seal seat to the specified
torque.

Solar Sensor, HVAC > < Service Port HVAC|Service Precautions|Page 3909