Quest Minivan GXE V6-2960cc 3.0L SOHC MFI (VG30E) (1997)
Cooling fan relays-1, -2 and -3
Check continuity between terminals (3) and (5).
Conditions / Continuity
12V direct current supply between terminals (1) & (2) / Yes
No Current supply / No
If NG, replace relay.