Sentra L4-1.8L (QG18DE) SULEV (2003)
Shift Solenoid: Service and Repair
Control Valve Assembly and Accumulators
REMOVAL
1. Drain ATF from transaxle.
2. Remove oil pan and gasket.
^
Always replace oil pan bolts as they are self-sealing bolts.
3. Disconnect A/T solenoid valve harness connector.
4. Remove stopper ring from A/T solenoid harness terminal body.
5. Remove A/T solenoid harness by pushing terminal body into transmission case.