Refrigerant: Description and Operation

Refrigeration System

Refrigeration Cycle

REFRIGERATION CYCLE

Refrigerant Flow

The refrigerant flows in the standard pattern. Refrigerant flows through the compressor, condenser, liquid tank, expansion valve, evaporator, and back to
the compressor. The refrigerant evaporation through the evaporator coil is controlled by an externally equalized expansion valve, located inside the
evaporator case.

Freeze Protection

The compressor cycles on and off to maintain the evaporator temperature within a specified range. When the evaporator coil temperature falls below a
specified point, the thermo control amplifier interrupts the compressor operation. When the evaporator coil temperature rises above the specification, the
thermo control amplifier allows compressor operation.

Refrigerant System Protection

Dual Pressure Switch

The refrigerant system is protected against excessively high or low pressure. The protection is effected by a dual pressure switch located on the liquid
tank. If the pressure falls out of specifications, the switch opens to interrupt compressor operation.

Pressure Relief Valve

The refrigerant system is also protected by a pressure relief valve located on the flexible high pressure hose near the compressor. When the pressure of
refrigerant in the system increases to an abnormal level [more than 3,727 kPa (38 kg/sq.cm, 540 psi)], the release port on the pressure relief valve
automatically opens and releases refrigerant into the atmosphere.