Aurora V6-214 3.5L VIN H SFI (2001)
Service Port HVAC: Service and Repair
SERVICE PORTS REPLACEMENT
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Remove the service fitting from the line.
INSTALLATION PROCEDURE
1. Lubricate the O-ring using 525 refrigerant oil.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the service fitting to the line.
Tighten
Tighten the fitting to 12 N.m (9 lb ft).
3. Recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
4. Leak test the fittings of the component using the J 39400-A.