Cutlass V6-191 3.1L VIN M SFI (1998)
Blower Motor Switch: Service and Repair
Remove or Disconnect
1. Negative battery cable.
2. Accessory trim plate.
3. Control assembly screws and pull control assembly away from the instrument panel.
4. Electrical connection
5. Blower switch retaining screws and blower switch
Install or Connect
1. Blower switch and retaining screws.
Tighten
^
Screws, fully driven, seated and not stripped.
2. Electrical connection.
3. Control assembly and retaining screws.
Tighten
^
Screws to 2 N.m (18 lb in).
4. Accessory trim plate.
5. Negative battery cable.
Tighten
^
Bolt to 16 N.m (12 lb ft).