Cooling System - Fan Inoperative, Terminal Damaged

SUBJECT

INOPERATIVE COOLING FAN DUE TO

NUMBER: 85-T-44

DAMAGED TERMINAL

DATE:

Sept. 27, 1985

MODELS/YEARS  1985 CUTLASS CIERA WITH 2.5L L-4 ENGINE

(VIN CODE R); 1985 FIRENZA WITH 1.8L L-4

SECTION: 8A

ENGINE (VIN CODE 0)

Some 1985 Firenza or Cutlass Ciera models may experience an inoperative or an intermittent operating cooling fan..

This condition may be caused by a damaged (bent or deformed) terminal on the red no. 2 circuit wire in the cooling fan relay connector. This red no. 2
circuit wire is located in either cavity D or E of the connector, depending on the model and the harness and relay that is used.

To repair this condition, the following procedure should be followed:

1.

Disconnect negative battery cable.

2.

Disconnect cooling fan relay.