Cutlass Ciera FWD V6-260 4.3L DSL (1982)
FIGURE 3 - HOUSING REFERENCE MARK (TYPICAL) AND RACK CENTERING MEASUREMENT
vInspect
When pinion and valve assembly is fully seated, flat or notch in stub shaft and first mark on housing must line up while the rack is centered in the
housing. Refer to measurement "A" to verify proper rack position. (See Figure 3.)
7.
While holding the stub shaft, thread lock nut onto pinion and torque to 35 N-m (26 ft.lbs.).