Air Door Actuator / Motor: Description and Operation
Vacuum Motor

The vacuum motor is spring loaded to hold the motor link out to the full cold (65 degrees F) position. 

As vacuum is applied to the motor, the link is pulled into the motor. An increase in vacuum causes the motor link to be pulled further into the motor.
Then the programmer output crank moves toward full heat and the temperature door will be positioned for warmer outlet air flow. Approximately 7-1/2
inches of vacuum are required to pull the motor link completely into the motor for full heat (84 degrees F) operation. A venting valve in the vacuum
motor prevents the motor from locking in the full heat position. 