336890301 > < Engine - Calibrating the Seem Belt Tension Gauge
Page 2
background image

Reading from Step 3

=        

25 SEEM units

Reading from Step 4

=        

26 SEEM units

Add Steps 3 and 4

=        

51 SEEM units

Value engraved on 

calibration strip

=        

55

Difference

=        -

4 SEEM units

Correction factor

=        -

4 divided by 2 = -2 SEEM units

In this example, if the belt being adjusted has a specification of 50 SEEM units, then it must be tightened until the SEEM C.TRONIC gauge
reads 48 units.

336890301 > < Engine - Calibrating the Seem Belt Tension Gauge