Acclaim V6-181 3.0L SOHC (1990)
Wiper Switch: Testing and Inspection
Fig. 7 Wiper Switch Continuity Chart. 89 Dynasty & New Yorker
Fig. 8 Wiper Switch Continuity Chart. 89 Dynasty & New Yorker
1. On models with an instrument panel switch, remove switch to gain access to terminals.
2. On models with a column mounted switch, disconnect electrical connector to switch at body wiring harness connector.
3. On all models, operate switch in all positions, and check continuity between terminals with an ohmmeter. On instrument panel mounted switches,
ground is the switch body.
4. If continuity is not as specified in charts, replace switch.