Conquest L4-2555cc 2.6L SOHC Turbo (1984)
Fig. 28 Positioning Air Selection Damper Lever
10. Reverse procedure to install, noting the following:
a. Place mode selector lever in defrost/vent position, then with mode selection damper lever pressed in direction indicated by arrow connect
mode selection control wire to lever and secure outer cable using clip.
b. Place temperature control lever in "COOL" position, then with blend air damper lever pressed in direction indicated by arrow connect
temperature control wire to lever and secure outer cable using clip.
c. Place air selection lever in recirculation position, then with air selection damper lever pressed in direction indicated by arrow connect air
selection control wire to lever and secure outer cable using clip.