Inspect the wiper module drain tubes (2), and the lower plenum drain hose to ensure they are fully seated and not restricted, kinked or plugged, see
Figure 1.

PARTS REQUIRED:

AR (1)

05010842AA

Deflector

AR (2)

0153185

Screw

AR (1)

04885330AA

Super Kleen

AR (1)

04318025

Sealant, Silicone

REPAIR PROCEDURE:

This bulletin involves adjusting the hood and/or cowl cover and/or removing any restriction from the wiper module drain tubes (2) and/or lower plenum
drain hose and possibly installing a deflector in the cowl plenum.

POLICY: Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:

Labor Operation No:

23-50-02-93 Procedure A

0.5 Hrs.

23-50-02-94 Procedure B

1.2 Hrs.

FAILURE CODE: XX - Service Adjustment